Understanding Backflow Prevention

What Is Backflow?

Backflow is an unwanted reversal of water flow. Instead of remaining in the intended system, water can move toward the drinking-water supply when pressure conditions change.

Backsiphonage can occur when supply pressure falls, such as during a water-main problem or heavy demand. Backpressure can occur when downstream pressure exceeds the supply pressure. Pumps, elevation and thermal expansion can contribute to those conditions.

Cross-connection control identifies connections through which unwanted water or substances could enter the potable supply and provides suitable protection.

Air bubbles rising through water.

Pollutants and Contaminants

Backflow risks vary with what is connected to the water supply. Some substances affect water quality without creating a health hazard; others can introduce a health hazard.

Irrigation chemicals, animal waste, process fluids and substances added to closed systems are examples of material that should remain separate from drinking water. The nature of the connection helps determine the protection required.

Water dripping from a cupped hand.

Irrigation Systems

Sprinklers and hoses can contact soil, fertilizers, pesticides and other material in the landscape. That creates a potential route back toward the drinking-water system if protection is missing or not working.

The appropriate assembly depends on the system, elevation, pressure conditions and water-supplier requirements. We test and repair irrigation assemblies and assess installation or replacement needs for the specific property.

Irrigation sprinkler watering a lawn.

Fire-Suppression Systems

Water in a fire-suppression system can remain stagnant, and some systems contain antifreeze or other additives. Backflow protection separates that system from the potable supply.

Foxfield Plumbing Inc tests and repairs fire-suppression backflow assemblies. We refer fire-system installation and replacement work to appropriately licensed fire contractors. Assembly selection and changes must account for the applicable system and water-supplier requirements.

Fire sprinkler head spraying water.

Domestic Water Supplies

A property’s domestic supply may serve irrigation, heating equipment, cooling equipment, fountains or other systems with different hazards. Protection at the property boundary and protection within the property serve different purposes.

Containment helps protect the public supply from a property. Isolation addresses a particular system or connection within it. A containment assembly does not by itself resolve every internal cross-connection.

Water suppliers apply their own requirements to the properties they serve. We identify the applicable district and consider its requirements alongside the actual installation.

Water being poured into a drinking glass.

Boilers and Other Connected Systems

Boiler and closed-loop water can contain treatment chemicals, antifreeze, sediment or other substances that do not belong in the drinking-water supply. Makeup and fill connections need suitable protection.

The required protection depends on the application and applicable requirements. We assess the connected system rather than assuming that a basic check valve is suitable for every boiler or process connection.

Boiler and water heater in a mechanical room.